regulator: palmas: configure enable time for LDOs
authorLaxman Dewangan <ldewangan@nvidia.com>
Tue, 10 Sep 2013 11:18:07 +0000 (16:48 +0530)
committerMark Brown <broonie@linaro.org>
Mon, 16 Sep 2013 23:31:03 +0000 (00:31 +0100)
As per datasheet (Referred TPS65913), the on-time for LDO is
500micro second. If LDO6 is in vibrator mode then the on-time
is 2000us.

Set the enable_time on regulator descriptor accordingly.

Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: Mark Brown <broonie@linaro.org>
drivers/regulator/palmas-regulator.c

index 3c08e1b5b289773eaeef7c3f0ed603b8e79c2f57..76ce09c6b594784aed1c652a9a2a2ec068c96d8c 100644 (file)
@@ -1127,6 +1127,7 @@ static int palmas_regulators_probe(struct platform_device *pdev)
                        pmic->desc[id].min_uV = 900000;
                        pmic->desc[id].uV_step = 50000;
                        pmic->desc[id].linear_min_sel = 1;
+                       pmic->desc[id].enable_time = 500;
                        pmic->desc[id].vsel_reg =
                                        PALMAS_BASE_TO_REG(PALMAS_LDO_BASE,
                                                palmas_regs_info[id].vsel_addr);
@@ -1145,6 +1146,11 @@ static int palmas_regulators_probe(struct platform_device *pdev)
                                pmic->desc[id].min_uV = 450000;
                                pmic->desc[id].uV_step = 25000;
                        }
+
+                       /* LOD6 in vibrator mode will have enable time 2000us */
+                       if (pdata && pdata->ldo6_vibrator &&
+                               (id == PALMAS_REG_LDO6))
+                               pmic->desc[id].enable_time = 2000;
                } else {
                        pmic->desc[id].n_voltages = 1;
                        if (reg_init && reg_init->roof_floor)