As per datasheet (Referred TPS65913), the on-time for LDO is
500micro second. If LDO6 is in vibrator mode then the on-time
is 2000us.
Set the enable_time on regulator descriptor accordingly.
Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: Mark Brown <broonie@linaro.org>
pmic->desc[id].min_uV = 900000;
pmic->desc[id].uV_step = 50000;
pmic->desc[id].linear_min_sel = 1;
pmic->desc[id].min_uV = 900000;
pmic->desc[id].uV_step = 50000;
pmic->desc[id].linear_min_sel = 1;
+ pmic->desc[id].enable_time = 500;
pmic->desc[id].vsel_reg =
PALMAS_BASE_TO_REG(PALMAS_LDO_BASE,
palmas_regs_info[id].vsel_addr);
pmic->desc[id].vsel_reg =
PALMAS_BASE_TO_REG(PALMAS_LDO_BASE,
palmas_regs_info[id].vsel_addr);
pmic->desc[id].min_uV = 450000;
pmic->desc[id].uV_step = 25000;
}
pmic->desc[id].min_uV = 450000;
pmic->desc[id].uV_step = 25000;
}
+
+ /* LOD6 in vibrator mode will have enable time 2000us */
+ if (pdata && pdata->ldo6_vibrator &&
+ (id == PALMAS_REG_LDO6))
+ pmic->desc[id].enable_time = 2000;
} else {
pmic->desc[id].n_voltages = 1;
if (reg_init && reg_init->roof_floor)
} else {
pmic->desc[id].n_voltages = 1;
if (reg_init && reg_init->roof_floor)