thermal: cpu_cooling: fix improper order during initialization
authorLukasz Luba <lukasz.luba@arm.com>
Tue, 31 May 2016 10:32:02 +0000 (11:32 +0100)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Wed, 27 Jul 2016 16:47:29 +0000 (09:47 -0700)
commit f840ab18bdf2e415dac21d09fbbbd2873111bd48 upstream.

The freq_table array is not populated before calling
thermal_of_cooling_register. The code which populates the freq table was
introduced in commit f6859014.
This should be done before registering new thermal cooling device.
The log shows effects of this wrong decision.
[    2.172614] cpu cpu1: Failed to get voltage for frequency 1984518656000: -34
[    2.220863] cpu cpu0: Failed to get voltage for frequency 1984524416000: -34

Fixes: f6859014c7e7 ("thermal: cpu_cooling: Store frequencies in descending order")
Signed-off-by: Lukasz Luba <lukasz.luba@arm.com>
Acked-by: Javi Merino <javi.merino@arm.com>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/thermal/cpu_cooling.c

index 6ceac4f2d4b227d52045632992568d08ea158c5b..5b4b47ed948ba2735870e78e50fe860c14e7d4a7 100644 (file)
@@ -857,14 +857,6 @@ __cpufreq_cooling_register(struct device_node *np,
                goto free_power_table;
        }
 
-       snprintf(dev_name, sizeof(dev_name), "thermal-cpufreq-%d",
-                cpufreq_dev->id);
-
-       cool_dev = thermal_of_cooling_device_register(np, dev_name, cpufreq_dev,
-                                                     &cpufreq_cooling_ops);
-       if (IS_ERR(cool_dev))
-               goto remove_idr;
-
        /* Fill freq-table in descending order of frequencies */
        for (i = 0, freq = -1; i <= cpufreq_dev->max_level; i++) {
                freq = find_next_max(table, freq);
@@ -877,6 +869,14 @@ __cpufreq_cooling_register(struct device_node *np,
                        pr_debug("%s: freq:%u KHz\n", __func__, freq);
        }
 
+       snprintf(dev_name, sizeof(dev_name), "thermal-cpufreq-%d",
+                cpufreq_dev->id);
+
+       cool_dev = thermal_of_cooling_device_register(np, dev_name, cpufreq_dev,
+                                                     &cpufreq_cooling_ops);
+       if (IS_ERR(cool_dev))
+               goto remove_idr;
+
        cpufreq_dev->clipped_freq = cpufreq_dev->freq_table[0];
        cpufreq_dev->cool_dev = cool_dev;