xhci: Use correct SLOT ID when handling a reset device command
authorMathias Nyman <mathias.nyman@linux.intel.com>
Tue, 24 Jun 2014 14:14:40 +0000 (17:14 +0300)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Tue, 24 Jun 2014 16:29:35 +0000 (12:29 -0400)
Command completion events normally include command completion status,
SLOT_ID, and a pointer to the original command. Reset device command
completion SLOT_ID may be zero according to xhci specs 4.6.11.

VIA controllers set the SLOT_ID to zero, triggering a WARN_ON in the
command completion handler.

Use the SLOT ID found from the original command instead.

This patch should be applied to stable kernels since 3.13 that contain
the commit 20e7acb13ff48fbc884d5918c3697c27de63922a
"xhci: use completion event's slot id rather than dig it out of command"

Cc: stable@vger.kernel.org # 3.13
Reported-by: Saran Neti <sarannmr@gmail.com>
Tested-by: Saran Neti <sarannmr@gmail.com>
Signed-off-by: Mathias Nyman <mathias.nyman@linux.intel.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/usb/host/xhci-ring.c

index d67ff71209f52a33d3b40fd5d79930f40d0ed8ad..71657d39a5782b8543416e1d9d5bfc6d1031a910 100644 (file)
@@ -1433,8 +1433,11 @@ static void handle_cmd_completion(struct xhci_hcd *xhci,
                xhci_handle_cmd_reset_ep(xhci, slot_id, cmd_trb, cmd_comp_code);
                break;
        case TRB_RESET_DEV:
-               WARN_ON(slot_id != TRB_TO_SLOT_ID(
-                               le32_to_cpu(cmd_trb->generic.field[3])));
+               /* SLOT_ID field in reset device cmd completion event TRB is 0.
+                * Use the SLOT_ID from the command TRB instead (xhci 4.6.11)
+                */
+               slot_id = TRB_TO_SLOT_ID(
+                               le32_to_cpu(cmd_trb->generic.field[3]));
                xhci_handle_cmd_reset_dev(xhci, slot_id, event);
                break;
        case TRB_NEC_GET_FW: