Merge commit 'ed30f24e8d07d30aa3e69d1f508f4d7bd2e8ea14' of git://git.linaro.org/landi...
[firefly-linux-kernel-4.4.55.git] / include / linux / thermal.h
1 /*
2  *  thermal.h  ($Revision: 0 $)
3  *
4  *  Copyright (C) 2008  Intel Corp
5  *  Copyright (C) 2008  Zhang Rui <rui.zhang@intel.com>
6  *  Copyright (C) 2008  Sujith Thomas <sujith.thomas@intel.com>
7  *
8  * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
9  *  This program is free software; you can redistribute it and/or modify
10  *  it under the terms of the GNU General Public License as published by
11  *  the Free Software Foundation; version 2 of the License.
12  *
13  *  This program is distributed in the hope that it will be useful, but
14  *  WITHOUT ANY WARRANTY; without even the implied warranty of
15  *  MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the GNU
16  *  General Public License for more details.
17  *
18  *  You should have received a copy of the GNU General Public License along
19  *  with this program; if not, write to the Free Software Foundation, Inc.,
20  *  59 Temple Place, Suite 330, Boston, MA 02111-1307 USA.
21  *
22  * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
23  */
24
25 #ifndef __THERMAL_H__
26 #define __THERMAL_H__
27
28 #include <linux/idr.h>
29 #include <linux/device.h>
30 #include <linux/workqueue.h>
31
32 #define THERMAL_TRIPS_NONE      -1
33 #define THERMAL_MAX_TRIPS       12
34 #define THERMAL_NAME_LENGTH     20
35
36 /* invalid cooling state */
37 #define THERMAL_CSTATE_INVALID -1UL
38
39 /* No upper/lower limit requirement */
40 #define THERMAL_NO_LIMIT        THERMAL_CSTATE_INVALID
41
42 /* Unit conversion macros */
43 #define KELVIN_TO_CELSIUS(t)    (long)(((long)t-2732 >= 0) ?    \
44                                 ((long)t-2732+5)/10 : ((long)t-2732-5)/10)
45 #define CELSIUS_TO_KELVIN(t)    ((t)*10+2732)
46
47 /* Adding event notification support elements */
48 #define THERMAL_GENL_FAMILY_NAME                "thermal_event"
49 #define THERMAL_GENL_VERSION                    0x01
50 #define THERMAL_GENL_MCAST_GROUP_NAME           "thermal_mc_grp"
51
52 /* Default Thermal Governor */
53 #if defined(CONFIG_THERMAL_DEFAULT_GOV_STEP_WISE)
54 #define DEFAULT_THERMAL_GOVERNOR       "step_wise"
55 #elif defined(CONFIG_THERMAL_DEFAULT_GOV_FAIR_SHARE)
56 #define DEFAULT_THERMAL_GOVERNOR       "fair_share"
57 #elif defined(CONFIG_THERMAL_DEFAULT_GOV_USER_SPACE)
58 #define DEFAULT_THERMAL_GOVERNOR       "user_space"
59 #endif
60
61 struct thermal_zone_device;
62 struct thermal_cooling_device;
63
64 enum thermal_device_mode {
65         THERMAL_DEVICE_DISABLED = 0,
66         THERMAL_DEVICE_ENABLED,
67 };
68
69 enum thermal_trip_type {
70         THERMAL_TRIP_ACTIVE = 0,
71         THERMAL_TRIP_PASSIVE,
72         THERMAL_TRIP_HOT,
73         THERMAL_TRIP_CRITICAL,
74 };
75
76 enum thermal_trend {
77         THERMAL_TREND_STABLE, /* temperature is stable */
78         THERMAL_TREND_RAISING, /* temperature is raising */
79         THERMAL_TREND_DROPPING, /* temperature is dropping */
80         THERMAL_TREND_RAISE_FULL, /* apply highest cooling action */
81         THERMAL_TREND_DROP_FULL, /* apply lowest cooling action */
82 };
83
84 /* Events supported by Thermal Netlink */
85 enum events {
86         THERMAL_AUX0,
87         THERMAL_AUX1,
88         THERMAL_CRITICAL,
89         THERMAL_DEV_FAULT,
90 };
91
92 /* attributes of thermal_genl_family */
93 enum {
94         THERMAL_GENL_ATTR_UNSPEC,
95         THERMAL_GENL_ATTR_EVENT,
96         __THERMAL_GENL_ATTR_MAX,
97 };
98 #define THERMAL_GENL_ATTR_MAX (__THERMAL_GENL_ATTR_MAX - 1)
99
100 /* commands supported by the thermal_genl_family */
101 enum {
102         THERMAL_GENL_CMD_UNSPEC,
103         THERMAL_GENL_CMD_EVENT,
104         __THERMAL_GENL_CMD_MAX,
105 };
106 #define THERMAL_GENL_CMD_MAX (__THERMAL_GENL_CMD_MAX - 1)
107
108 struct thermal_zone_device_ops {
109         int (*bind) (struct thermal_zone_device *,
110                      struct thermal_cooling_device *);
111         int (*unbind) (struct thermal_zone_device *,
112                        struct thermal_cooling_device *);
113         int (*get_temp) (struct thermal_zone_device *, unsigned long *);
114         int (*get_mode) (struct thermal_zone_device *,
115                          enum thermal_device_mode *);
116         int (*set_mode) (struct thermal_zone_device *,
117                 enum thermal_device_mode);
118         int (*get_trip_type) (struct thermal_zone_device *, int,
119                 enum thermal_trip_type *);
120         int (*get_trip_temp) (struct thermal_zone_device *, int,
121                               unsigned long *);
122         int (*set_trip_temp) (struct thermal_zone_device *, int,
123                               unsigned long);
124         int (*get_trip_hyst) (struct thermal_zone_device *, int,
125                               unsigned long *);
126         int (*set_trip_hyst) (struct thermal_zone_device *, int,
127                               unsigned long);
128         int (*get_crit_temp) (struct thermal_zone_device *, unsigned long *);
129         int (*set_emul_temp) (struct thermal_zone_device *, unsigned long);
130         int (*get_trend) (struct thermal_zone_device *, int,
131                           enum thermal_trend *);
132         int (*notify) (struct thermal_zone_device *, int,
133                        enum thermal_trip_type);
134 };
135
136 struct thermal_cooling_device_ops {
137         int (*get_max_state) (struct thermal_cooling_device *, unsigned long *);
138         int (*get_cur_state) (struct thermal_cooling_device *, unsigned long *);
139         int (*set_cur_state) (struct thermal_cooling_device *, unsigned long);
140 };
141
142 struct thermal_cooling_device {
143         int id;
144         char type[THERMAL_NAME_LENGTH];
145         struct device device;
146         void *devdata;
147         const struct thermal_cooling_device_ops *ops;
148         bool updated; /* true if the cooling device does not need update */
149         struct mutex lock; /* protect thermal_instances list */
150         struct list_head thermal_instances;
151         struct list_head node;
152 };
153
154 struct thermal_attr {
155         struct device_attribute attr;
156         char name[THERMAL_NAME_LENGTH];
157 };
158
159 struct thermal_zone_device {
160         int id;
161         char type[THERMAL_NAME_LENGTH];
162         struct device device;
163         struct thermal_attr *trip_temp_attrs;
164         struct thermal_attr *trip_type_attrs;
165         struct thermal_attr *trip_hyst_attrs;
166         void *devdata;
167         int trips;
168         int passive_delay;
169         int polling_delay;
170         int temperature;
171         int last_temperature;
172         int emul_temperature;
173         int passive;
174         unsigned int forced_passive;
175         const struct thermal_zone_device_ops *ops;
176         const struct thermal_zone_params *tzp;
177         struct thermal_governor *governor;
178         struct list_head thermal_instances;
179         struct idr idr;
180         struct mutex lock; /* protect thermal_instances list */
181         struct list_head node;
182         struct delayed_work poll_queue;
183 };
184
185 /* Structure that holds thermal governor information */
186 struct thermal_governor {
187         char name[THERMAL_NAME_LENGTH];
188         int (*throttle)(struct thermal_zone_device *tz, int trip);
189         struct list_head        governor_list;
190 };
191
192 /* Structure that holds binding parameters for a zone */
193 struct thermal_bind_params {
194         struct thermal_cooling_device *cdev;
195
196         /*
197          * This is a measure of 'how effectively these devices can
198          * cool 'this' thermal zone. The shall be determined by platform
199          * characterization. This is on a 'percentage' scale.
200          * See Documentation/thermal/sysfs-api.txt for more information.
201          */
202         int weight;
203
204         /*
205          * This is a bit mask that gives the binding relation between this
206          * thermal zone and cdev, for a particular trip point.
207          * See Documentation/thermal/sysfs-api.txt for more information.
208          */
209         int trip_mask;
210         int (*match) (struct thermal_zone_device *tz,
211                         struct thermal_cooling_device *cdev);
212 };
213
214 /* Structure to define Thermal Zone parameters */
215 struct thermal_zone_params {
216         char governor_name[THERMAL_NAME_LENGTH];
217         int num_tbps;   /* Number of tbp entries */
218         struct thermal_bind_params *tbp;
219 };
220
221 struct thermal_genl_event {
222         u32 orig;
223         enum events event;
224 };
225
226 /* Function declarations */
227 struct thermal_zone_device *thermal_zone_device_register(const char *, int, int,
228                 void *, const struct thermal_zone_device_ops *,
229                 const struct thermal_zone_params *, int, int);
230 void thermal_zone_device_unregister(struct thermal_zone_device *);
231
232 int thermal_zone_bind_cooling_device(struct thermal_zone_device *, int,
233                                      struct thermal_cooling_device *,
234                                      unsigned long, unsigned long);
235 int thermal_zone_unbind_cooling_device(struct thermal_zone_device *, int,
236                                        struct thermal_cooling_device *);
237 void thermal_zone_device_update(struct thermal_zone_device *);
238
239 struct thermal_cooling_device *thermal_cooling_device_register(char *, void *,
240                 const struct thermal_cooling_device_ops *);
241 void thermal_cooling_device_unregister(struct thermal_cooling_device *);
242 struct thermal_zone_device *thermal_zone_get_zone_by_name(const char *name);
243 int thermal_zone_get_temp(struct thermal_zone_device *tz, unsigned long *temp);
244
245 int get_tz_trend(struct thermal_zone_device *, int);
246 struct thermal_instance *get_thermal_instance(struct thermal_zone_device *,
247                 struct thermal_cooling_device *, int);
248 void thermal_cdev_update(struct thermal_cooling_device *);
249 void thermal_notify_framework(struct thermal_zone_device *, int);
250
251 #ifdef CONFIG_NET
252 extern int thermal_generate_netlink_event(struct thermal_zone_device *tz,
253                                                 enum events event);
254 #else
255 static inline int thermal_generate_netlink_event(struct thermal_zone_device *tz,
256                                                 enum events event)
257 {
258         return 0;
259 }
260 #endif
261
262 #endif /* __THERMAL_H__ */