Merge branch 'next' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux
[firefly-linux-kernel-4.4.55.git] / drivers / thermal / cpu_cooling.c
1 /*
2  *  linux/drivers/thermal/cpu_cooling.c
3  *
4  *  Copyright (C) 2012  Samsung Electronics Co., Ltd(http://www.samsung.com)
5  *  Copyright (C) 2012  Amit Daniel <amit.kachhap@linaro.org>
6  *
7  *  Copyright (C) 2014  Viresh Kumar <viresh.kumar@linaro.org>
8  *
9  * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
10  *  This program is free software; you can redistribute it and/or modify
11  *  it under the terms of the GNU General Public License as published by
12  *  the Free Software Foundation; version 2 of the License.
13  *
14  *  This program is distributed in the hope that it will be useful, but
15  *  WITHOUT ANY WARRANTY; without even the implied warranty of
16  *  MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the GNU
17  *  General Public License for more details.
18  *
19  *  You should have received a copy of the GNU General Public License along
20  *  with this program; if not, write to the Free Software Foundation, Inc.,
21  *  59 Temple Place, Suite 330, Boston, MA 02111-1307 USA.
22  *
23  * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
24  */
25 #include <linux/module.h>
26 #include <linux/thermal.h>
27 #include <linux/cpufreq.h>
28 #include <linux/err.h>
29 #include <linux/pm_opp.h>
30 #include <linux/slab.h>
31 #include <linux/cpu.h>
32 #include <linux/cpu_cooling.h>
33
34 #include <trace/events/thermal.h>
35
36 /*
37  * Cooling state <-> CPUFreq frequency
38  *
39  * Cooling states are translated to frequencies throughout this driver and this
40  * is the relation between them.
41  *
42  * Highest cooling state corresponds to lowest possible frequency.
43  *
44  * i.e.
45  *      level 0 --> 1st Max Freq
46  *      level 1 --> 2nd Max Freq
47  *      ...
48  */
49
50 /**
51  * struct power_table - frequency to power conversion
52  * @frequency:  frequency in KHz
53  * @power:      power in mW
54  *
55  * This structure is built when the cooling device registers and helps
56  * in translating frequency to power and viceversa.
57  */
58 struct power_table {
59         u32 frequency;
60         u32 power;
61 };
62
63 /**
64  * struct cpufreq_cooling_device - data for cooling device with cpufreq
65  * @id: unique integer value corresponding to each cpufreq_cooling_device
66  *      registered.
67  * @cool_dev: thermal_cooling_device pointer to keep track of the
68  *      registered cooling device.
69  * @cpufreq_state: integer value representing the current state of cpufreq
70  *      cooling devices.
71  * @clipped_freq: integer value representing the absolute value of the clipped
72  *      frequency.
73  * @max_level: maximum cooling level. One less than total number of valid
74  *      cpufreq frequencies.
75  * @allowed_cpus: all the cpus involved for this cpufreq_cooling_device.
76  * @node: list_head to link all cpufreq_cooling_device together.
77  * @last_load: load measured by the latest call to cpufreq_get_actual_power()
78  * @time_in_idle: previous reading of the absolute time that this cpu was idle
79  * @time_in_idle_timestamp: wall time of the last invocation of
80  *      get_cpu_idle_time_us()
81  * @dyn_power_table: array of struct power_table for frequency to power
82  *      conversion, sorted in ascending order.
83  * @dyn_power_table_entries: number of entries in the @dyn_power_table array
84  * @cpu_dev: the first cpu_device from @allowed_cpus that has OPPs registered
85  * @plat_get_static_power: callback to calculate the static power
86  *
87  * This structure is required for keeping information of each registered
88  * cpufreq_cooling_device.
89  */
90 struct cpufreq_cooling_device {
91         int id;
92         struct thermal_cooling_device *cool_dev;
93         unsigned int cpufreq_state;
94         unsigned int clipped_freq;
95         unsigned int max_level;
96         unsigned int *freq_table;       /* In descending order */
97         struct cpumask allowed_cpus;
98         struct list_head node;
99         u32 last_load;
100         u64 *time_in_idle;
101         u64 *time_in_idle_timestamp;
102         struct power_table *dyn_power_table;
103         int dyn_power_table_entries;
104         struct device *cpu_dev;
105         get_static_t plat_get_static_power;
106 };
107 static DEFINE_IDR(cpufreq_idr);
108 static DEFINE_MUTEX(cooling_cpufreq_lock);
109
110 static unsigned int cpufreq_dev_count;
111
112 static DEFINE_MUTEX(cooling_list_lock);
113 static LIST_HEAD(cpufreq_dev_list);
114
115 /**
116  * get_idr - function to get a unique id.
117  * @idr: struct idr * handle used to create a id.
118  * @id: int * value generated by this function.
119  *
120  * This function will populate @id with an unique
121  * id, using the idr API.
122  *
123  * Return: 0 on success, an error code on failure.
124  */
125 static int get_idr(struct idr *idr, int *id)
126 {
127         int ret;
128
129         mutex_lock(&cooling_cpufreq_lock);
130         ret = idr_alloc(idr, NULL, 0, 0, GFP_KERNEL);
131         mutex_unlock(&cooling_cpufreq_lock);
132         if (unlikely(ret < 0))
133                 return ret;
134         *id = ret;
135
136         return 0;
137 }
138
139 /**
140  * release_idr - function to free the unique id.
141  * @idr: struct idr * handle used for creating the id.
142  * @id: int value representing the unique id.
143  */
144 static void release_idr(struct idr *idr, int id)
145 {
146         mutex_lock(&cooling_cpufreq_lock);
147         idr_remove(idr, id);
148         mutex_unlock(&cooling_cpufreq_lock);
149 }
150
151 /* Below code defines functions to be used for cpufreq as cooling device */
152
153 /**
154  * get_level: Find the level for a particular frequency
155  * @cpufreq_dev: cpufreq_dev for which the property is required
156  * @freq: Frequency
157  *
158  * Return: level on success, THERMAL_CSTATE_INVALID on error.
159  */
160 static unsigned long get_level(struct cpufreq_cooling_device *cpufreq_dev,
161                                unsigned int freq)
162 {
163         unsigned long level;
164
165         for (level = 0; level <= cpufreq_dev->max_level; level++) {
166                 if (freq == cpufreq_dev->freq_table[level])
167                         return level;
168
169                 if (freq > cpufreq_dev->freq_table[level])
170                         break;
171         }
172
173         return THERMAL_CSTATE_INVALID;
174 }
175
176 /**
177  * cpufreq_cooling_get_level - for a given cpu, return the cooling level.
178  * @cpu: cpu for which the level is required
179  * @freq: the frequency of interest
180  *
181  * This function will match the cooling level corresponding to the
182  * requested @freq and return it.
183  *
184  * Return: The matched cooling level on success or THERMAL_CSTATE_INVALID
185  * otherwise.
186  */
187 unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq)
188 {
189         struct cpufreq_cooling_device *cpufreq_dev;
190
191         mutex_lock(&cooling_list_lock);
192         list_for_each_entry(cpufreq_dev, &cpufreq_dev_list, node) {
193                 if (cpumask_test_cpu(cpu, &cpufreq_dev->allowed_cpus)) {
194                         mutex_unlock(&cooling_list_lock);
195                         return get_level(cpufreq_dev, freq);
196                 }
197         }
198         mutex_unlock(&cooling_list_lock);
199
200         pr_err("%s: cpu:%d not part of any cooling device\n", __func__, cpu);
201         return THERMAL_CSTATE_INVALID;
202 }
203 EXPORT_SYMBOL_GPL(cpufreq_cooling_get_level);
204
205 /**
206  * cpufreq_thermal_notifier - notifier callback for cpufreq policy change.
207  * @nb: struct notifier_block * with callback info.
208  * @event: value showing cpufreq event for which this function invoked.
209  * @data: callback-specific data
210  *
211  * Callback to hijack the notification on cpufreq policy transition.
212  * Every time there is a change in policy, we will intercept and
213  * update the cpufreq policy with thermal constraints.
214  *
215  * Return: 0 (success)
216  */
217 static int cpufreq_thermal_notifier(struct notifier_block *nb,
218                                     unsigned long event, void *data)
219 {
220         struct cpufreq_policy *policy = data;
221         unsigned long clipped_freq;
222         struct cpufreq_cooling_device *cpufreq_dev;
223
224         if (event != CPUFREQ_ADJUST)
225                 return NOTIFY_DONE;
226
227         mutex_lock(&cooling_list_lock);
228         list_for_each_entry(cpufreq_dev, &cpufreq_dev_list, node) {
229                 if (!cpumask_test_cpu(policy->cpu, &cpufreq_dev->allowed_cpus))
230                         continue;
231
232                 /*
233                  * policy->max is the maximum allowed frequency defined by user
234                  * and clipped_freq is the maximum that thermal constraints
235                  * allow.
236                  *
237                  * If clipped_freq is lower than policy->max, then we need to
238                  * readjust policy->max.
239                  *
240                  * But, if clipped_freq is greater than policy->max, we don't
241                  * need to do anything.
242                  */
243                 clipped_freq = cpufreq_dev->clipped_freq;
244
245                 if (policy->max > clipped_freq)
246                         cpufreq_verify_within_limits(policy, 0, clipped_freq);
247                 break;
248         }
249         mutex_unlock(&cooling_list_lock);
250
251         return NOTIFY_OK;
252 }
253
254 /**
255  * build_dyn_power_table() - create a dynamic power to frequency table
256  * @cpufreq_device:     the cpufreq cooling device in which to store the table
257  * @capacitance: dynamic power coefficient for these cpus
258  *
259  * Build a dynamic power to frequency table for this cpu and store it
260  * in @cpufreq_device.  This table will be used in cpu_power_to_freq() and
261  * cpu_freq_to_power() to convert between power and frequency
262  * efficiently.  Power is stored in mW, frequency in KHz.  The
263  * resulting table is in ascending order.
264  *
265  * Return: 0 on success, -EINVAL if there are no OPPs for any CPUs,
266  * -ENOMEM if we run out of memory or -EAGAIN if an OPP was
267  * added/enabled while the function was executing.
268  */
269 static int build_dyn_power_table(struct cpufreq_cooling_device *cpufreq_device,
270                                  u32 capacitance)
271 {
272         struct power_table *power_table;
273         struct dev_pm_opp *opp;
274         struct device *dev = NULL;
275         int num_opps = 0, cpu, i, ret = 0;
276         unsigned long freq;
277
278         for_each_cpu(cpu, &cpufreq_device->allowed_cpus) {
279                 dev = get_cpu_device(cpu);
280                 if (!dev) {
281                         dev_warn(&cpufreq_device->cool_dev->device,
282                                  "No cpu device for cpu %d\n", cpu);
283                         continue;
284                 }
285
286                 num_opps = dev_pm_opp_get_opp_count(dev);
287                 if (num_opps > 0)
288                         break;
289                 else if (num_opps < 0)
290                         return num_opps;
291         }
292
293         if (num_opps == 0)
294                 return -EINVAL;
295
296         power_table = kcalloc(num_opps, sizeof(*power_table), GFP_KERNEL);
297         if (!power_table)
298                 return -ENOMEM;
299
300         rcu_read_lock();
301
302         for (freq = 0, i = 0;
303              opp = dev_pm_opp_find_freq_ceil(dev, &freq), !IS_ERR(opp);
304              freq++, i++) {
305                 u32 freq_mhz, voltage_mv;
306                 u64 power;
307
308                 if (i >= num_opps) {
309                         rcu_read_unlock();
310                         ret = -EAGAIN;
311                         goto free_power_table;
312                 }
313
314                 freq_mhz = freq / 1000000;
315                 voltage_mv = dev_pm_opp_get_voltage(opp) / 1000;
316
317                 /*
318                  * Do the multiplication with MHz and millivolt so as
319                  * to not overflow.
320                  */
321                 power = (u64)capacitance * freq_mhz * voltage_mv * voltage_mv;
322                 do_div(power, 1000000000);
323
324                 /* frequency is stored in power_table in KHz */
325                 power_table[i].frequency = freq / 1000;
326
327                 /* power is stored in mW */
328                 power_table[i].power = power;
329         }
330
331         rcu_read_unlock();
332
333         if (i != num_opps) {
334                 ret = PTR_ERR(opp);
335                 goto free_power_table;
336         }
337
338         cpufreq_device->cpu_dev = dev;
339         cpufreq_device->dyn_power_table = power_table;
340         cpufreq_device->dyn_power_table_entries = i;
341
342         return 0;
343
344 free_power_table:
345         kfree(power_table);
346
347         return ret;
348 }
349
350 static u32 cpu_freq_to_power(struct cpufreq_cooling_device *cpufreq_device,
351                              u32 freq)
352 {
353         int i;
354         struct power_table *pt = cpufreq_device->dyn_power_table;
355
356         for (i = 1; i < cpufreq_device->dyn_power_table_entries; i++)
357                 if (freq < pt[i].frequency)
358                         break;
359
360         return pt[i - 1].power;
361 }
362
363 static u32 cpu_power_to_freq(struct cpufreq_cooling_device *cpufreq_device,
364                              u32 power)
365 {
366         int i;
367         struct power_table *pt = cpufreq_device->dyn_power_table;
368
369         for (i = 1; i < cpufreq_device->dyn_power_table_entries; i++)
370                 if (power < pt[i].power)
371                         break;
372
373         return pt[i - 1].frequency;
374 }
375
376 /**
377  * get_load() - get load for a cpu since last updated
378  * @cpufreq_device:     &struct cpufreq_cooling_device for this cpu
379  * @cpu:        cpu number
380  *
381  * Return: The average load of cpu @cpu in percentage since this
382  * function was last called.
383  */
384 static u32 get_load(struct cpufreq_cooling_device *cpufreq_device, int cpu)
385 {
386         u32 load;
387         u64 now, now_idle, delta_time, delta_idle;
388
389         now_idle = get_cpu_idle_time(cpu, &now, 0);
390         delta_idle = now_idle - cpufreq_device->time_in_idle[cpu];
391         delta_time = now - cpufreq_device->time_in_idle_timestamp[cpu];
392
393         if (delta_time <= delta_idle)
394                 load = 0;
395         else
396                 load = div64_u64(100 * (delta_time - delta_idle), delta_time);
397
398         cpufreq_device->time_in_idle[cpu] = now_idle;
399         cpufreq_device->time_in_idle_timestamp[cpu] = now;
400
401         return load;
402 }
403
404 /**
405  * get_static_power() - calculate the static power consumed by the cpus
406  * @cpufreq_device:     struct &cpufreq_cooling_device for this cpu cdev
407  * @tz:         thermal zone device in which we're operating
408  * @freq:       frequency in KHz
409  * @power:      pointer in which to store the calculated static power
410  *
411  * Calculate the static power consumed by the cpus described by
412  * @cpu_actor running at frequency @freq.  This function relies on a
413  * platform specific function that should have been provided when the
414  * actor was registered.  If it wasn't, the static power is assumed to
415  * be negligible.  The calculated static power is stored in @power.
416  *
417  * Return: 0 on success, -E* on failure.
418  */
419 static int get_static_power(struct cpufreq_cooling_device *cpufreq_device,
420                             struct thermal_zone_device *tz, unsigned long freq,
421                             u32 *power)
422 {
423         struct dev_pm_opp *opp;
424         unsigned long voltage;
425         struct cpumask *cpumask = &cpufreq_device->allowed_cpus;
426         unsigned long freq_hz = freq * 1000;
427
428         if (!cpufreq_device->plat_get_static_power ||
429             !cpufreq_device->cpu_dev) {
430                 *power = 0;
431                 return 0;
432         }
433
434         rcu_read_lock();
435
436         opp = dev_pm_opp_find_freq_exact(cpufreq_device->cpu_dev, freq_hz,
437                                          true);
438         voltage = dev_pm_opp_get_voltage(opp);
439
440         rcu_read_unlock();
441
442         if (voltage == 0) {
443                 dev_warn_ratelimited(cpufreq_device->cpu_dev,
444                                      "Failed to get voltage for frequency %lu: %ld\n",
445                                      freq_hz, IS_ERR(opp) ? PTR_ERR(opp) : 0);
446                 return -EINVAL;
447         }
448
449         return cpufreq_device->plat_get_static_power(cpumask, tz->passive_delay,
450                                                      voltage, power);
451 }
452
453 /**
454  * get_dynamic_power() - calculate the dynamic power
455  * @cpufreq_device:     &cpufreq_cooling_device for this cdev
456  * @freq:       current frequency
457  *
458  * Return: the dynamic power consumed by the cpus described by
459  * @cpufreq_device.
460  */
461 static u32 get_dynamic_power(struct cpufreq_cooling_device *cpufreq_device,
462                              unsigned long freq)
463 {
464         u32 raw_cpu_power;
465
466         raw_cpu_power = cpu_freq_to_power(cpufreq_device, freq);
467         return (raw_cpu_power * cpufreq_device->last_load) / 100;
468 }
469
470 /* cpufreq cooling device callback functions are defined below */
471
472 /**
473  * cpufreq_get_max_state - callback function to get the max cooling state.
474  * @cdev: thermal cooling device pointer.
475  * @state: fill this variable with the max cooling state.
476  *
477  * Callback for the thermal cooling device to return the cpufreq
478  * max cooling state.
479  *
480  * Return: 0 on success, an error code otherwise.
481  */
482 static int cpufreq_get_max_state(struct thermal_cooling_device *cdev,
483                                  unsigned long *state)
484 {
485         struct cpufreq_cooling_device *cpufreq_device = cdev->devdata;
486
487         *state = cpufreq_device->max_level;
488         return 0;
489 }
490
491 /**
492  * cpufreq_get_cur_state - callback function to get the current cooling state.
493  * @cdev: thermal cooling device pointer.
494  * @state: fill this variable with the current cooling state.
495  *
496  * Callback for the thermal cooling device to return the cpufreq
497  * current cooling state.
498  *
499  * Return: 0 on success, an error code otherwise.
500  */
501 static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev,
502                                  unsigned long *state)
503 {
504         struct cpufreq_cooling_device *cpufreq_device = cdev->devdata;
505
506         *state = cpufreq_device->cpufreq_state;
507
508         return 0;
509 }
510
511 /**
512  * cpufreq_set_cur_state - callback function to set the current cooling state.
513  * @cdev: thermal cooling device pointer.
514  * @state: set this variable to the current cooling state.
515  *
516  * Callback for the thermal cooling device to change the cpufreq
517  * current cooling state.
518  *
519  * Return: 0 on success, an error code otherwise.
520  */
521 static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,
522                                  unsigned long state)
523 {
524         struct cpufreq_cooling_device *cpufreq_device = cdev->devdata;
525         unsigned int cpu = cpumask_any(&cpufreq_device->allowed_cpus);
526         unsigned int clip_freq;
527
528         /* Request state should be less than max_level */
529         if (WARN_ON(state > cpufreq_device->max_level))
530                 return -EINVAL;
531
532         /* Check if the old cooling action is same as new cooling action */
533         if (cpufreq_device->cpufreq_state == state)
534                 return 0;
535
536         clip_freq = cpufreq_device->freq_table[state];
537         cpufreq_device->cpufreq_state = state;
538         cpufreq_device->clipped_freq = clip_freq;
539
540         cpufreq_update_policy(cpu);
541
542         return 0;
543 }
544
545 /**
546  * cpufreq_get_requested_power() - get the current power
547  * @cdev:       &thermal_cooling_device pointer
548  * @tz:         a valid thermal zone device pointer
549  * @power:      pointer in which to store the resulting power
550  *
551  * Calculate the current power consumption of the cpus in milliwatts
552  * and store it in @power.  This function should actually calculate
553  * the requested power, but it's hard to get the frequency that
554  * cpufreq would have assigned if there were no thermal limits.
555  * Instead, we calculate the current power on the assumption that the
556  * immediate future will look like the immediate past.
557  *
558  * We use the current frequency and the average load since this
559  * function was last called.  In reality, there could have been
560  * multiple opps since this function was last called and that affects
561  * the load calculation.  While it's not perfectly accurate, this
562  * simplification is good enough and works.  REVISIT this, as more
563  * complex code may be needed if experiments show that it's not
564  * accurate enough.
565  *
566  * Return: 0 on success, -E* if getting the static power failed.
567  */
568 static int cpufreq_get_requested_power(struct thermal_cooling_device *cdev,
569                                        struct thermal_zone_device *tz,
570                                        u32 *power)
571 {
572         unsigned long freq;
573         int i = 0, cpu, ret;
574         u32 static_power, dynamic_power, total_load = 0;
575         struct cpufreq_cooling_device *cpufreq_device = cdev->devdata;
576         u32 *load_cpu = NULL;
577
578         cpu = cpumask_any_and(&cpufreq_device->allowed_cpus, cpu_online_mask);
579
580         /*
581          * All the CPUs are offline, thus the requested power by
582          * the cdev is 0
583          */
584         if (cpu >= nr_cpu_ids) {
585                 *power = 0;
586                 return 0;
587         }
588
589         freq = cpufreq_quick_get(cpu);
590
591         if (trace_thermal_power_cpu_get_power_enabled()) {
592                 u32 ncpus = cpumask_weight(&cpufreq_device->allowed_cpus);
593
594                 load_cpu = kcalloc(ncpus, sizeof(*load_cpu), GFP_KERNEL);
595         }
596
597         for_each_cpu(cpu, &cpufreq_device->allowed_cpus) {
598                 u32 load;
599
600                 if (cpu_online(cpu))
601                         load = get_load(cpufreq_device, cpu);
602                 else
603                         load = 0;
604
605                 total_load += load;
606                 if (trace_thermal_power_cpu_limit_enabled() && load_cpu)
607                         load_cpu[i] = load;
608
609                 i++;
610         }
611
612         cpufreq_device->last_load = total_load;
613
614         dynamic_power = get_dynamic_power(cpufreq_device, freq);
615         ret = get_static_power(cpufreq_device, tz, freq, &static_power);
616         if (ret) {
617                 kfree(load_cpu);
618                 return ret;
619         }
620
621         if (load_cpu) {
622                 trace_thermal_power_cpu_get_power(
623                         &cpufreq_device->allowed_cpus,
624                         freq, load_cpu, i, dynamic_power, static_power);
625
626                 kfree(load_cpu);
627         }
628
629         *power = static_power + dynamic_power;
630         return 0;
631 }
632
633 /**
634  * cpufreq_state2power() - convert a cpu cdev state to power consumed
635  * @cdev:       &thermal_cooling_device pointer
636  * @tz:         a valid thermal zone device pointer
637  * @state:      cooling device state to be converted
638  * @power:      pointer in which to store the resulting power
639  *
640  * Convert cooling device state @state into power consumption in
641  * milliwatts assuming 100% load.  Store the calculated power in
642  * @power.
643  *
644  * Return: 0 on success, -EINVAL if the cooling device state could not
645  * be converted into a frequency or other -E* if there was an error
646  * when calculating the static power.
647  */
648 static int cpufreq_state2power(struct thermal_cooling_device *cdev,
649                                struct thermal_zone_device *tz,
650                                unsigned long state, u32 *power)
651 {
652         unsigned int freq, num_cpus;
653         cpumask_t cpumask;
654         u32 static_power, dynamic_power;
655         int ret;
656         struct cpufreq_cooling_device *cpufreq_device = cdev->devdata;
657
658         cpumask_and(&cpumask, &cpufreq_device->allowed_cpus, cpu_online_mask);
659         num_cpus = cpumask_weight(&cpumask);
660
661         /* None of our cpus are online, so no power */
662         if (num_cpus == 0) {
663                 *power = 0;
664                 return 0;
665         }
666
667         freq = cpufreq_device->freq_table[state];
668         if (!freq)
669                 return -EINVAL;
670
671         dynamic_power = cpu_freq_to_power(cpufreq_device, freq) * num_cpus;
672         ret = get_static_power(cpufreq_device, tz, freq, &static_power);
673         if (ret)
674                 return ret;
675
676         *power = static_power + dynamic_power;
677         return 0;
678 }
679
680 /**
681  * cpufreq_power2state() - convert power to a cooling device state
682  * @cdev:       &thermal_cooling_device pointer
683  * @tz:         a valid thermal zone device pointer
684  * @power:      power in milliwatts to be converted
685  * @state:      pointer in which to store the resulting state
686  *
687  * Calculate a cooling device state for the cpus described by @cdev
688  * that would allow them to consume at most @power mW and store it in
689  * @state.  Note that this calculation depends on external factors
690  * such as the cpu load or the current static power.  Calling this
691  * function with the same power as input can yield different cooling
692  * device states depending on those external factors.
693  *
694  * Return: 0 on success, -ENODEV if no cpus are online or -EINVAL if
695  * the calculated frequency could not be converted to a valid state.
696  * The latter should not happen unless the frequencies available to
697  * cpufreq have changed since the initialization of the cpu cooling
698  * device.
699  */
700 static int cpufreq_power2state(struct thermal_cooling_device *cdev,
701                                struct thermal_zone_device *tz, u32 power,
702                                unsigned long *state)
703 {
704         unsigned int cpu, cur_freq, target_freq;
705         int ret;
706         s32 dyn_power;
707         u32 last_load, normalised_power, static_power;
708         struct cpufreq_cooling_device *cpufreq_device = cdev->devdata;
709
710         cpu = cpumask_any_and(&cpufreq_device->allowed_cpus, cpu_online_mask);
711
712         /* None of our cpus are online */
713         if (cpu >= nr_cpu_ids)
714                 return -ENODEV;
715
716         cur_freq = cpufreq_quick_get(cpu);
717         ret = get_static_power(cpufreq_device, tz, cur_freq, &static_power);
718         if (ret)
719                 return ret;
720
721         dyn_power = power - static_power;
722         dyn_power = dyn_power > 0 ? dyn_power : 0;
723         last_load = cpufreq_device->last_load ?: 1;
724         normalised_power = (dyn_power * 100) / last_load;
725         target_freq = cpu_power_to_freq(cpufreq_device, normalised_power);
726
727         *state = cpufreq_cooling_get_level(cpu, target_freq);
728         if (*state == THERMAL_CSTATE_INVALID) {
729                 dev_warn_ratelimited(&cdev->device,
730                                      "Failed to convert %dKHz for cpu %d into a cdev state\n",
731                                      target_freq, cpu);
732                 return -EINVAL;
733         }
734
735         trace_thermal_power_cpu_limit(&cpufreq_device->allowed_cpus,
736                                       target_freq, *state, power);
737         return 0;
738 }
739
740 /* Bind cpufreq callbacks to thermal cooling device ops */
741 static struct thermal_cooling_device_ops cpufreq_cooling_ops = {
742         .get_max_state = cpufreq_get_max_state,
743         .get_cur_state = cpufreq_get_cur_state,
744         .set_cur_state = cpufreq_set_cur_state,
745 };
746
747 /* Notifier for cpufreq policy change */
748 static struct notifier_block thermal_cpufreq_notifier_block = {
749         .notifier_call = cpufreq_thermal_notifier,
750 };
751
752 static unsigned int find_next_max(struct cpufreq_frequency_table *table,
753                                   unsigned int prev_max)
754 {
755         struct cpufreq_frequency_table *pos;
756         unsigned int max = 0;
757
758         cpufreq_for_each_valid_entry(pos, table) {
759                 if (pos->frequency > max && pos->frequency < prev_max)
760                         max = pos->frequency;
761         }
762
763         return max;
764 }
765
766 /**
767  * __cpufreq_cooling_register - helper function to create cpufreq cooling device
768  * @np: a valid struct device_node to the cooling device device tree node
769  * @clip_cpus: cpumask of cpus where the frequency constraints will happen.
770  * Normally this should be same as cpufreq policy->related_cpus.
771  * @capacitance: dynamic power coefficient for these cpus
772  * @plat_static_func: function to calculate the static power consumed by these
773  *                    cpus (optional)
774  *
775  * This interface function registers the cpufreq cooling device with the name
776  * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
777  * cooling devices. It also gives the opportunity to link the cooling device
778  * with a device tree node, in order to bind it via the thermal DT code.
779  *
780  * Return: a valid struct thermal_cooling_device pointer on success,
781  * on failure, it returns a corresponding ERR_PTR().
782  */
783 static struct thermal_cooling_device *
784 __cpufreq_cooling_register(struct device_node *np,
785                         const struct cpumask *clip_cpus, u32 capacitance,
786                         get_static_t plat_static_func)
787 {
788         struct thermal_cooling_device *cool_dev;
789         struct cpufreq_cooling_device *cpufreq_dev;
790         char dev_name[THERMAL_NAME_LENGTH];
791         struct cpufreq_frequency_table *pos, *table;
792         unsigned int freq, i, num_cpus;
793         int ret;
794
795         table = cpufreq_frequency_get_table(cpumask_first(clip_cpus));
796         if (!table) {
797                 pr_debug("%s: CPUFreq table not found\n", __func__);
798                 return ERR_PTR(-EPROBE_DEFER);
799         }
800
801         cpufreq_dev = kzalloc(sizeof(*cpufreq_dev), GFP_KERNEL);
802         if (!cpufreq_dev)
803                 return ERR_PTR(-ENOMEM);
804
805         num_cpus = cpumask_weight(clip_cpus);
806         cpufreq_dev->time_in_idle = kcalloc(num_cpus,
807                                             sizeof(*cpufreq_dev->time_in_idle),
808                                             GFP_KERNEL);
809         if (!cpufreq_dev->time_in_idle) {
810                 cool_dev = ERR_PTR(-ENOMEM);
811                 goto free_cdev;
812         }
813
814         cpufreq_dev->time_in_idle_timestamp =
815                 kcalloc(num_cpus, sizeof(*cpufreq_dev->time_in_idle_timestamp),
816                         GFP_KERNEL);
817         if (!cpufreq_dev->time_in_idle_timestamp) {
818                 cool_dev = ERR_PTR(-ENOMEM);
819                 goto free_time_in_idle;
820         }
821
822         /* Find max levels */
823         cpufreq_for_each_valid_entry(pos, table)
824                 cpufreq_dev->max_level++;
825
826         cpufreq_dev->freq_table = kmalloc(sizeof(*cpufreq_dev->freq_table) *
827                                           cpufreq_dev->max_level, GFP_KERNEL);
828         if (!cpufreq_dev->freq_table) {
829                 cool_dev = ERR_PTR(-ENOMEM);
830                 goto free_time_in_idle_timestamp;
831         }
832
833         /* max_level is an index, not a counter */
834         cpufreq_dev->max_level--;
835
836         cpumask_copy(&cpufreq_dev->allowed_cpus, clip_cpus);
837
838         if (capacitance) {
839                 cpufreq_cooling_ops.get_requested_power =
840                         cpufreq_get_requested_power;
841                 cpufreq_cooling_ops.state2power = cpufreq_state2power;
842                 cpufreq_cooling_ops.power2state = cpufreq_power2state;
843                 cpufreq_dev->plat_get_static_power = plat_static_func;
844
845                 ret = build_dyn_power_table(cpufreq_dev, capacitance);
846                 if (ret) {
847                         cool_dev = ERR_PTR(ret);
848                         goto free_table;
849                 }
850         }
851
852         ret = get_idr(&cpufreq_idr, &cpufreq_dev->id);
853         if (ret) {
854                 cool_dev = ERR_PTR(ret);
855                 goto free_power_table;
856         }
857
858         snprintf(dev_name, sizeof(dev_name), "thermal-cpufreq-%d",
859                  cpufreq_dev->id);
860
861         cool_dev = thermal_of_cooling_device_register(np, dev_name, cpufreq_dev,
862                                                       &cpufreq_cooling_ops);
863         if (IS_ERR(cool_dev))
864                 goto remove_idr;
865
866         /* Fill freq-table in descending order of frequencies */
867         for (i = 0, freq = -1; i <= cpufreq_dev->max_level; i++) {
868                 freq = find_next_max(table, freq);
869                 cpufreq_dev->freq_table[i] = freq;
870
871                 /* Warn for duplicate entries */
872                 if (!freq)
873                         pr_warn("%s: table has duplicate entries\n", __func__);
874                 else
875                         pr_debug("%s: freq:%u KHz\n", __func__, freq);
876         }
877
878         cpufreq_dev->clipped_freq = cpufreq_dev->freq_table[0];
879         cpufreq_dev->cool_dev = cool_dev;
880
881         mutex_lock(&cooling_cpufreq_lock);
882
883         mutex_lock(&cooling_list_lock);
884         list_add(&cpufreq_dev->node, &cpufreq_dev_list);
885         mutex_unlock(&cooling_list_lock);
886
887         /* Register the notifier for first cpufreq cooling device */
888         if (!cpufreq_dev_count++)
889                 cpufreq_register_notifier(&thermal_cpufreq_notifier_block,
890                                           CPUFREQ_POLICY_NOTIFIER);
891         mutex_unlock(&cooling_cpufreq_lock);
892
893         return cool_dev;
894
895 remove_idr:
896         release_idr(&cpufreq_idr, cpufreq_dev->id);
897 free_power_table:
898         kfree(cpufreq_dev->dyn_power_table);
899 free_table:
900         kfree(cpufreq_dev->freq_table);
901 free_time_in_idle_timestamp:
902         kfree(cpufreq_dev->time_in_idle_timestamp);
903 free_time_in_idle:
904         kfree(cpufreq_dev->time_in_idle);
905 free_cdev:
906         kfree(cpufreq_dev);
907
908         return cool_dev;
909 }
910
911 /**
912  * cpufreq_cooling_register - function to create cpufreq cooling device.
913  * @clip_cpus: cpumask of cpus where the frequency constraints will happen.
914  *
915  * This interface function registers the cpufreq cooling device with the name
916  * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
917  * cooling devices.
918  *
919  * Return: a valid struct thermal_cooling_device pointer on success,
920  * on failure, it returns a corresponding ERR_PTR().
921  */
922 struct thermal_cooling_device *
923 cpufreq_cooling_register(const struct cpumask *clip_cpus)
924 {
925         return __cpufreq_cooling_register(NULL, clip_cpus, 0, NULL);
926 }
927 EXPORT_SYMBOL_GPL(cpufreq_cooling_register);
928
929 /**
930  * of_cpufreq_cooling_register - function to create cpufreq cooling device.
931  * @np: a valid struct device_node to the cooling device device tree node
932  * @clip_cpus: cpumask of cpus where the frequency constraints will happen.
933  *
934  * This interface function registers the cpufreq cooling device with the name
935  * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
936  * cooling devices. Using this API, the cpufreq cooling device will be
937  * linked to the device tree node provided.
938  *
939  * Return: a valid struct thermal_cooling_device pointer on success,
940  * on failure, it returns a corresponding ERR_PTR().
941  */
942 struct thermal_cooling_device *
943 of_cpufreq_cooling_register(struct device_node *np,
944                             const struct cpumask *clip_cpus)
945 {
946         if (!np)
947                 return ERR_PTR(-EINVAL);
948
949         return __cpufreq_cooling_register(np, clip_cpus, 0, NULL);
950 }
951 EXPORT_SYMBOL_GPL(of_cpufreq_cooling_register);
952
953 /**
954  * cpufreq_power_cooling_register() - create cpufreq cooling device with power extensions
955  * @clip_cpus:  cpumask of cpus where the frequency constraints will happen
956  * @capacitance:        dynamic power coefficient for these cpus
957  * @plat_static_func:   function to calculate the static power consumed by these
958  *                      cpus (optional)
959  *
960  * This interface function registers the cpufreq cooling device with
961  * the name "thermal-cpufreq-%x".  This api can support multiple
962  * instances of cpufreq cooling devices.  Using this function, the
963  * cooling device will implement the power extensions by using a
964  * simple cpu power model.  The cpus must have registered their OPPs
965  * using the OPP library.
966  *
967  * An optional @plat_static_func may be provided to calculate the
968  * static power consumed by these cpus.  If the platform's static
969  * power consumption is unknown or negligible, make it NULL.
970  *
971  * Return: a valid struct thermal_cooling_device pointer on success,
972  * on failure, it returns a corresponding ERR_PTR().
973  */
974 struct thermal_cooling_device *
975 cpufreq_power_cooling_register(const struct cpumask *clip_cpus, u32 capacitance,
976                                get_static_t plat_static_func)
977 {
978         return __cpufreq_cooling_register(NULL, clip_cpus, capacitance,
979                                 plat_static_func);
980 }
981 EXPORT_SYMBOL(cpufreq_power_cooling_register);
982
983 /**
984  * of_cpufreq_power_cooling_register() - create cpufreq cooling device with power extensions
985  * @np: a valid struct device_node to the cooling device device tree node
986  * @clip_cpus:  cpumask of cpus where the frequency constraints will happen
987  * @capacitance:        dynamic power coefficient for these cpus
988  * @plat_static_func:   function to calculate the static power consumed by these
989  *                      cpus (optional)
990  *
991  * This interface function registers the cpufreq cooling device with
992  * the name "thermal-cpufreq-%x".  This api can support multiple
993  * instances of cpufreq cooling devices.  Using this API, the cpufreq
994  * cooling device will be linked to the device tree node provided.
995  * Using this function, the cooling device will implement the power
996  * extensions by using a simple cpu power model.  The cpus must have
997  * registered their OPPs using the OPP library.
998  *
999  * An optional @plat_static_func may be provided to calculate the
1000  * static power consumed by these cpus.  If the platform's static
1001  * power consumption is unknown or negligible, make it NULL.
1002  *
1003  * Return: a valid struct thermal_cooling_device pointer on success,
1004  * on failure, it returns a corresponding ERR_PTR().
1005  */
1006 struct thermal_cooling_device *
1007 of_cpufreq_power_cooling_register(struct device_node *np,
1008                                   const struct cpumask *clip_cpus,
1009                                   u32 capacitance,
1010                                   get_static_t plat_static_func)
1011 {
1012         if (!np)
1013                 return ERR_PTR(-EINVAL);
1014
1015         return __cpufreq_cooling_register(np, clip_cpus, capacitance,
1016                                 plat_static_func);
1017 }
1018 EXPORT_SYMBOL(of_cpufreq_power_cooling_register);
1019
1020 /**
1021  * cpufreq_cooling_unregister - function to remove cpufreq cooling device.
1022  * @cdev: thermal cooling device pointer.
1023  *
1024  * This interface function unregisters the "thermal-cpufreq-%x" cooling device.
1025  */
1026 void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
1027 {
1028         struct cpufreq_cooling_device *cpufreq_dev;
1029
1030         if (!cdev)
1031                 return;
1032
1033         cpufreq_dev = cdev->devdata;
1034
1035         /* Unregister the notifier for the last cpufreq cooling device */
1036         mutex_lock(&cooling_cpufreq_lock);
1037         if (!--cpufreq_dev_count)
1038                 cpufreq_unregister_notifier(&thermal_cpufreq_notifier_block,
1039                                             CPUFREQ_POLICY_NOTIFIER);
1040
1041         mutex_lock(&cooling_list_lock);
1042         list_del(&cpufreq_dev->node);
1043         mutex_unlock(&cooling_list_lock);
1044
1045         mutex_unlock(&cooling_cpufreq_lock);
1046
1047         thermal_cooling_device_unregister(cpufreq_dev->cool_dev);
1048         release_idr(&cpufreq_idr, cpufreq_dev->id);
1049         kfree(cpufreq_dev->dyn_power_table);
1050         kfree(cpufreq_dev->time_in_idle_timestamp);
1051         kfree(cpufreq_dev->time_in_idle);
1052         kfree(cpufreq_dev->freq_table);
1053         kfree(cpufreq_dev);
1054 }
1055 EXPORT_SYMBOL_GPL(cpufreq_cooling_unregister);