1 Generic Thermal Sysfs driver How To
2 ===================================
3
4 Written by Sujith Thomas <sujith.thomas@intel.com>, Zhang Rui <rui.zhang@intel.com>
5
6 Updated: 2 January 2008
7
8 Copyright (c)  2008 Intel Corporation
9
10
11 0. Introduction
12
13 The generic thermal sysfs provides a set of interfaces for thermal zone
14 devices (sensors) and thermal cooling devices (fan, processor...) to register
15 with the thermal management solution and to be a part of it.
16
17 This how-to focuses on enabling new thermal zone and cooling devices to
18 participate in thermal management.
19 This solution is platform independent and any type of thermal zone devices
20 and cooling devices should be able to make use of the infrastructure.
21
22 The main task of the thermal sysfs driver is to expose thermal zone attributes
23 as well as cooling device attributes to the user space.
24 An intelligent thermal management application can make decisions based on
25 inputs from thermal zone attributes (the current temperature and trip point
26 temperature) and throttle appropriate devices.
27
28 [0-*]   denotes any positive number starting from 0
29 [1-*]   denotes any positive number starting from 1
30
31 1. thermal sysfs driver interface functions
32
33 1.1 thermal zone device interface
34 1.1.1 struct thermal_zone_device *thermal_zone_device_register(char *type,
35                 int trips, int mask, void *devdata,
36                 struct thermal_zone_device_ops *ops,
37                 const struct thermal_zone_params *tzp,
38                 int passive_delay, int polling_delay))
39
40     This interface function adds a new thermal zone device (sensor) to
41     /sys/class/thermal folder as thermal_zone[0-*]. It tries to bind all the
42     thermal cooling devices registered at the same time.
43
44     type: the thermal zone type.
45     trips: the total number of trip points this thermal zone supports.
46     mask: Bit string: If 'n'th bit is set, then trip point 'n' is writeable.
47     devdata: device private data
48     ops: thermal zone device call-backs.
49         .bind: bind the thermal zone device with a thermal cooling device.
50         .unbind: unbind the thermal zone device with a thermal cooling device.
51         .get_temp: get the current temperature of the thermal zone.
52         .get_mode: get the current mode (enabled/disabled) of the thermal zone.
53             - "enabled" means the kernel thermal management is enabled.
54             - "disabled" will prevent kernel thermal driver action upon trip points
55               so that user applications can take charge of thermal management.
56         .set_mode: set the mode (enabled/disabled) of the thermal zone.
57         .get_trip_type: get the type of certain trip point.
58         .get_trip_temp: get the temperature above which the certain trip point
59                         will be fired.
60         .set_emul_temp: set the emulation temperature which helps in debugging
61                         different threshold temperature points.
62     tzp: thermal zone platform parameters.
63     passive_delay: number of milliseconds to wait between polls when
64         performing passive cooling.
65     polling_delay: number of milliseconds to wait between polls when checking
66         whether trip points have been crossed (0 for interrupt driven systems).
67
68
69 1.1.2 void thermal_zone_device_unregister(struct thermal_zone_device *tz)
70
71     This interface function removes the thermal zone device.
72     It deletes the corresponding entry form /sys/class/thermal folder and
73     unbind all the thermal cooling devices it uses.
74
75 1.2 thermal cooling device interface
76 1.2.1 struct thermal_cooling_device *thermal_cooling_device_register(char *name,
77                 void *devdata, struct thermal_cooling_device_ops *)
78
79     This interface function adds a new thermal cooling device (fan/processor/...)
80     to /sys/class/thermal/ folder as cooling_device[0-*]. It tries to bind itself
81     to all the thermal zone devices register at the same time.
82     name: the cooling device name.
83     devdata: device private data.
84     ops: thermal cooling devices call-backs.
85         .get_max_state: get the Maximum throttle state of the cooling device.
86         .get_cur_state: get the Current throttle state of the cooling device.
87         .set_cur_state: set the Current throttle state of the cooling device.
88
89 1.2.2 void thermal_cooling_device_unregister(struct thermal_cooling_device *cdev)
90
91     This interface function remove the thermal cooling device.
92     It deletes the corresponding entry form /sys/class/thermal folder and
93     unbind itself from all the thermal zone devices using it.
94
95 1.3 interface for binding a thermal zone device with a thermal cooling device
96 1.3.1 int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz,
97         int trip, struct thermal_cooling_device *cdev,
98         unsigned long upper, unsigned long lower);
99
100     This interface function bind a thermal cooling device to the certain trip
101     point of a thermal zone device.
102     This function is usually called in the thermal zone device .bind callback.
103     tz: the thermal zone device
104     cdev: thermal cooling device
105     trip: indicates which trip point the cooling devices is associated with
106           in this thermal zone.
107     upper:the Maximum cooling state for this trip point.
108           THERMAL_NO_LIMIT means no upper limit,
109           and the cooling device can be in max_state.
110     lower:the Minimum cooling state can be used for this trip point.
111           THERMAL_NO_LIMIT means no lower limit,
112           and the cooling device can be in cooling state 0.
113
114 1.3.2 int thermal_zone_unbind_cooling_device(struct thermal_zone_device *tz,
115                 int trip, struct thermal_cooling_device *cdev);
116
117     This interface function unbind a thermal cooling device from the certain
118     trip point of a thermal zone device. This function is usually called in
119     the thermal zone device .unbind callback.
120     tz: the thermal zone device
121     cdev: thermal cooling device
122     trip: indicates which trip point the cooling devices is associated with
123           in this thermal zone.
124
125 1.4 Thermal Zone Parameters
126 1.4.1 struct thermal_bind_params
127     This structure defines the following parameters that are used to bind
128     a zone with a cooling device for a particular trip point.
129     .cdev: The cooling device pointer
130     .weight: The 'influence' of a particular cooling device on this zone.
131              This is on a percentage scale. The sum of all these weights
132              (for a particular zone) cannot exceed 100.
133     .trip_mask:This is a bit mask that gives the binding relation between
134                this thermal zone and cdev, for a particular trip point.
135                If nth bit is set, then the cdev and thermal zone are bound
136                for trip point n.
137     .match: This call back returns success(0) if the 'tz and cdev' need to
138             be bound, as per platform data.
139 1.4.2 struct thermal_zone_params
140     This structure defines the platform level parameters for a thermal zone.
141     This data, for each thermal zone should come from the platform layer.
142     This is an optional feature where some platforms can choose not to
143     provide this data.
144     .governor_name: Name of the thermal governor used for this zone
145     .num_tbps: Number of thermal_bind_params entries for this zone
146     .tbp: thermal_bind_params entries
147
148 2. sysfs attributes structure
149
150 RO      read only value
151 RW      read/write value
152
153 Thermal sysfs attributes will be represented under /sys/class/thermal.
154 Hwmon sysfs I/F extension is also available under /sys/class/hwmon
155 if hwmon is compiled in or built as a module.
156
157 Thermal zone device sys I/F, created once it's registered:
158 /sys/class/thermal/thermal_zone[0-*]:
159     |---type:                   Type of the thermal zone
160     |---temp:                   Current temperature
161     |---mode:                   Working mode of the thermal zone
162     |---policy:                 Thermal governor used for this zone
163     |---trip_point_[0-*]_temp:  Trip point temperature
164     |---trip_point_[0-*]_type:  Trip point type
165     |---trip_point_[0-*]_hyst:  Hysteresis value for this trip point
166     |---emul_temp:              Emulated temperature set node
167
168 Thermal cooling device sys I/F, created once it's registered:
169 /sys/class/thermal/cooling_device[0-*]:
170     |---type:                   Type of the cooling device(processor/fan/...)
171     |---max_state:              Maximum cooling state of the cooling device
172     |---cur_state:              Current cooling state of the cooling device
173
174
175 Then next two dynamic attributes are created/removed in pairs. They represent
176 the relationship between a thermal zone and its associated cooling device.
177 They are created/removed for each successful execution of
178 thermal_zone_bind_cooling_device/thermal_zone_unbind_cooling_device.
179
180 /sys/class/thermal/thermal_zone[0-*]:
181     |---cdev[0-*]:              [0-*]th cooling device in current thermal zone
182     |---cdev[0-*]_trip_point:   Trip point that cdev[0-*] is associated with
183
184 Besides the thermal zone device sysfs I/F and cooling device sysfs I/F,
185 the generic thermal driver also creates a hwmon sysfs I/F for each _type_
186 of thermal zone device. E.g. the generic thermal driver registers one hwmon
187 class device and build the associated hwmon sysfs I/F for all the registered
188 ACPI thermal zones.
189
190 /sys/class/hwmon/hwmon[0-*]:
191     |---name:                   The type of the thermal zone devices
192     |---temp[1-*]_input:        The current temperature of thermal zone [1-*]
193     |---temp[1-*]_critical:     The critical trip point of thermal zone [1-*]
194
195 Please read Documentation/hwmon/sysfs-interface for additional information.
196
197 ***************************
198 * Thermal zone attributes *
199 ***************************
200
201 type
202         Strings which represent the thermal zone type.
203         This is given by thermal zone driver as part of registration.
204         E.g: "acpitz" indicates it's an ACPI thermal device.
205         In order to keep it consistent with hwmon sys attribute; this should
206         be a short, lowercase string, not containing spaces nor dashes.
207         RO, Required
208
209 temp
210         Current temperature as reported by thermal zone (sensor).
211         Unit: millidegree Celsius
212         RO, Required
213
214 mode
215         One of the predefined values in [enabled, disabled].
216         This file gives information about the algorithm that is currently
217         managing the thermal zone. It can be either default kernel based
218         algorithm or user space application.
219         enabled         = enable Kernel Thermal management.
220         disabled        = Preventing kernel thermal zone driver actions upon
221                           trip points so that user application can take full
222                           charge of the thermal management.
223         RW, Optional
224
225 policy
226         One of the various thermal governors used for a particular zone.
227         RW, Required
228
229 trip_point_[0-*]_temp
230         The temperature above which trip point will be fired.
231         Unit: millidegree Celsius
232         RO, Optional
233
234 trip_point_[0-*]_type
235         Strings which indicate the type of the trip point.
236         E.g. it can be one of critical, hot, passive, active[0-*] for ACPI
237         thermal zone.
238         RO, Optional
239
240 trip_point_[0-*]_hyst
241         The hysteresis value for a trip point, represented as an integer
242         Unit: Celsius
243         RW, Optional
244
245 cdev[0-*]
246         Sysfs link to the thermal cooling device node where the sys I/F
247         for cooling device throttling control represents.
248         RO, Optional
249
250 cdev[0-*]_trip_point
251         The trip point with which cdev[0-*] is associated in this thermal
252         zone; -1 means the cooling device is not associated with any trip
253         point.
254         RO, Optional
255
256 passive
257         Attribute is only present for zones in which the passive cooling
258         policy is not supported by native thermal driver. Default is zero
259         and can be set to a temperature (in millidegrees) to enable a
260         passive trip point for the zone. Activation is done by polling with
261         an interval of 1 second.
262         Unit: millidegrees Celsius
263         Valid values: 0 (disabled) or greater than 1000
264         RW, Optional
265
266 emul_temp
267         Interface to set the emulated temperature method in thermal zone
268         (sensor). After setting this temperature, the thermal zone may pass
269         this temperature to platform emulation function if registered or
270         cache it locally. This is useful in debugging different temperature
271         threshold and its associated cooling action. This is write only node
272         and writing 0 on this node should disable emulation.
273         Unit: millidegree Celsius
274         WO, Optional
275
276           WARNING: Be careful while enabling this option on production systems,
277           because userland can easily disable the thermal policy by simply
278           flooding this sysfs node with low temperature values.
279
280 *****************************
281 * Cooling device attributes *
282 *****************************
283
284 type
285         String which represents the type of device, e.g:
286         - for generic ACPI: should be "Fan", "Processor" or "LCD"
287         - for memory controller device on intel_menlow platform:
288           should be "Memory controller".
289         RO, Required
290
291 max_state
292         The maximum permissible cooling state of this cooling device.
293         RO, Required
294
295 cur_state
296         The current cooling state of this cooling device.
297         The value can any integer numbers between 0 and max_state:
298         - cur_state == 0 means no cooling
299         - cur_state == max_state means the maximum cooling.
300         RW, Required
301
302 3. A simple implementation
303
304 ACPI thermal zone may support multiple trip points like critical, hot,
305 passive, active. If an ACPI thermal zone supports critical, passive,
306 active[0] and active[1] at the same time, it may register itself as a
307 thermal_zone_device (thermal_zone1) with 4 trip points in all.
308 It has one processor and one fan, which are both registered as
309 thermal_cooling_device.
310
311 If the processor is listed in _PSL method, and the fan is listed in _AL0
312 method, the sys I/F structure will be built like this:
313
314 /sys/class/thermal:
315
316 |thermal_zone1:
317     |---type:                   acpitz
318     |---temp:                   37000
319     |---mode:                   enabled
320     |---policy:                 step_wise
321     |---trip_point_0_temp:      100000
322     |---trip_point_0_type:      critical
323     |---trip_point_1_temp:      80000
324     |---trip_point_1_type:      passive
325     |---trip_point_2_temp:      70000
326     |---trip_point_2_type:      active0
327     |---trip_point_3_temp:      60000
328     |---trip_point_3_type:      active1
329     |---cdev0:                  --->/sys/class/thermal/cooling_device0
330     |---cdev0_trip_point:       1       /* cdev0 can be used for passive */
331     |---cdev1:                  --->/sys/class/thermal/cooling_device3
332     |---cdev1_trip_point:       2       /* cdev1 can be used for active[0]*/
333
334 |cooling_device0:
335     |---type:                   Processor
336     |---max_state:              8
337     |---cur_state:              0
338
339 |cooling_device3:
340     |---type:                   Fan
341     |---max_state:              2
342     |---cur_state:              0
343
344 /sys/class/hwmon:
345
346 |hwmon0:
347     |---name:                   acpitz
348     |---temp1_input:            37000
349     |---temp1_crit:             100000
350
351 4. Event Notification
352
353 The framework includes a simple notification mechanism, in the form of a
354 netlink event. Netlink socket initialization is done during the _init_
355 of the framework. Drivers which intend to use the notification mechanism
356 just need to call thermal_generate_netlink_event() with two arguments viz
357 (originator, event). The originator is a pointer to struct thermal_zone_device
358 from where the event has been originated. An integer which represents the
359 thermal zone device will be used in the message to identify the zone. The
360 event will be one of:{THERMAL_AUX0, THERMAL_AUX1, THERMAL_CRITICAL,
361 THERMAL_DEV_FAULT}. Notification can be sent when the current temperature
362 crosses any of the configured thresholds.
363
364 5. Export Symbol APIs:
365
366 5.1: get_tz_trend:
367 This function returns the trend of a thermal zone, i.e the rate of change
368 of temperature of the thermal zone. Ideally, the thermal sensor drivers
369 are supposed to implement the callback. If they don't, the thermal
370 framework calculated the trend by comparing the previous and the current
371 temperature values.
372
373 5.2:get_thermal_instance:
374 This function returns the thermal_instance corresponding to a given
375 {thermal_zone, cooling_device, trip_point} combination. Returns NULL
376 if such an instance does not exist.
377
378 5.3:thermal_notify_framework:
379 This function handles the trip events from sensor drivers. It starts
380 throttling the cooling devices according to the policy configured.
381 For CRITICAL and HOT trip points, this notifies the respective drivers,
382 and does actual throttling for other trip points i.e ACTIVE and PASSIVE.
383 The throttling policy is based on the configured platform data; if no
384 platform data is provided, this uses the step_wise throttling policy.
385
386 5.4:thermal_cdev_update:
387 This function serves as an arbitrator to set the state of a cooling