iio: humidity: hdc100x: fix IIO_TEMP channel reporting
authorMatt Ranostay <mranostay@gmail.com>
Fri, 27 May 2016 02:55:06 +0000 (19:55 -0700)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Wed, 27 Jul 2016 16:47:36 +0000 (09:47 -0700)
commitd2be6f6172de75b807b48ef391fb7542402f554e
treef10d75b86d2c6a41989b3798c2cd11bb7056c34e
parentf7ba3de17a6a81e9301648c3b024510d6df5be37
iio: humidity: hdc100x: fix IIO_TEMP channel reporting

commit 09bc0ddaab6cab0fa95a67d5535ec772e2671193 upstream.

IIO_TEMP channel was being incorrectly reported back as Celsius when it
should have been milliCelsius. This is via an incorrect scale value being
returned to userspace.

Signed-off-by: Matt Ranostay <mranostay@gmail.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/iio/humidity/hdc100x.c