e6bbe666673ab044a3d39ddb74e4d9a401cf1d6f upstream.
When a machine goes to S3/S4 after power-save is enabled, the runtime
PM refcount might be incorrectly decreased because the power-down
triggered soon after resume assumes that the controller was already
powered up, and issues the pm_notify down.
This patch fixes the incorrect pm_notify call simply by checking the
current value properly.
Signed-off-by: Takashi Iwai <tiwai@suse.de>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
spin_unlock(&codec->power_lock);
state = hda_call_codec_suspend(codec, true);
- codec->pm_down_notified = 0;
- if (!bus->power_keep_link_on && (state & AC_PWRST_CLK_STOP_OK)) {
+ if (!codec->pm_down_notified &&
+ !bus->power_keep_link_on && (state & AC_PWRST_CLK_STOP_OK)) {
codec->pm_down_notified = 1;
hda_call_pm_notify(bus, false);
}