staging: panel: fix lcd type
authorSudip Mukherjee <sudipm.mukherjee@gmail.com>
Tue, 24 Mar 2015 10:59:32 +0000 (16:29 +0530)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Wed, 13 May 2015 12:15:42 +0000 (05:15 -0700)
commit 2c20d92dad5db6440cfa88d811b69fd605240ce4 upstream.

the lcd type as defined in the Kconfig is not matching in the code.
as a result the rs, rw and en pins were getting interchanged.
Kconfig defines the value of PANEL_LCD to be 1 if we select custom
configuration but in the code LCD_TYPE_CUSTOM is defined as 5.

my hardware is LCD_TYPE_CUSTOM, but the pins were assigned to it
as pins of LCD_TYPE_OLD, and it was not working.
Now values are corrected with referenece to the values defined in
Kconfig and it is working.
checked on JHD204A lcd with LCD_TYPE_CUSTOM configuration.

Signed-off-by: Sudip Mukherjee <sudip@vectorindia.org>
Acked-by: Willy Tarreau <w@1wt.eu>
[wt: backport to 3.10 and 3.14]
Signed-off-by: Willy Tarreau <w@1wt.eu>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/staging/panel/panel.c

index c54df3948e20206d4b0cc8f9ed8b68253daf4acc..4d0a87b93b96b7e6b66ee40f2d24b2547e90f705 100644 (file)
@@ -275,11 +275,11 @@ static unsigned char lcd_bits[LCD_PORTS][LCD_BITS][BIT_STATES];
  * LCD types
  */
 #define LCD_TYPE_NONE          0
-#define LCD_TYPE_OLD           1
-#define LCD_TYPE_KS0074                2
-#define LCD_TYPE_HANTRONIX     3
-#define LCD_TYPE_NEXCOM                4
-#define LCD_TYPE_CUSTOM                5
+#define LCD_TYPE_CUSTOM                1
+#define LCD_TYPE_OLD           2
+#define LCD_TYPE_KS0074                3
+#define LCD_TYPE_HANTRONIX     4
+#define LCD_TYPE_NEXCOM                5
 
 /*
  * keypad types
@@ -457,8 +457,7 @@ MODULE_PARM_DESC(keypad_enabled, "Deprecated option, use keypad_type instead");
 static int lcd_type = -1;
 module_param(lcd_type, int, 0000);
 MODULE_PARM_DESC(lcd_type,
-                "LCD type: 0=none, 1=old //, 2=serial ks0074, "
-                "3=hantronix //, 4=nexcom //, 5=compiled-in");
+               "LCD type: 0=none, 1=compiled-in, 2=old, 3=serial ks0074, 4=hantronix, 5=nexcom");
 
 static int lcd_proto = -1;
 module_param(lcd_proto, int, 0000);