#define SMPS_CTRL_MODE_ECO 0x02
#define SMPS_CTRL_MODE_PWM 0x03
-/* These values are derived from the data sheet. And are the number of steps
- * where there is a voltage change, the ranges at beginning and end of register
- * max/min values where there are no change are ommitted.
- *
- * So they are basically (maxV-minV)/stepV
- */
-#define PALMAS_SMPS_NUM_VOLTAGES 117
+#define PALMAS_SMPS_NUM_VOLTAGES 122
#define PALMAS_SMPS10_NUM_VOLTAGES 2
#define PALMAS_LDO_NUM_VOLTAGES 50
pmic->desc[id].min_uV = 900000;
pmic->desc[id].uV_step = 50000;
pmic->desc[id].linear_min_sel = 1;
+ pmic->desc[id].enable_time = 500;
pmic->desc[id].vsel_reg =
PALMAS_BASE_TO_REG(PALMAS_LDO_BASE,
palmas_regs_info[id].vsel_addr);
pmic->desc[id].min_uV = 450000;
pmic->desc[id].uV_step = 25000;
}
+
+ /* LOD6 in vibrator mode will have enable time 2000us */
+ if (pdata && pdata->ldo6_vibrator &&
+ (id == PALMAS_REG_LDO6))
+ pmic->desc[id].enable_time = 2000;
} else {
pmic->desc[id].n_voltages = 1;
pmic->desc[id].ops = &palmas_ops_extreg;