thermal: hwmon: Properly report critical temperature in sysfs
authorKrzysztof Kozlowski <krzk@kernel.org>
Tue, 22 Nov 2016 17:22:44 +0000 (19:22 +0200)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Mon, 9 Jan 2017 07:07:44 +0000 (08:07 +0100)
commite692edec93c10b480a7cbd3c76de90da93b82075
treec16790c83c804f6e1ed513f2eba63111e219a3ed
parent9d9541d44a26dea009247e001ebd7775e2feeb37
thermal: hwmon: Properly report critical temperature in sysfs

commit f37fabb8643eaf8e3b613333a72f683770c85eca upstream.

In the critical sysfs entry the thermal hwmon was returning wrong
temperature to the user-space.  It was reporting the temperature of the
first trip point instead of the temperature of critical trip point.

For example:
/sys/class/hwmon/hwmon0/temp1_crit:50000
/sys/class/thermal/thermal_zone0/trip_point_0_temp:50000
/sys/class/thermal/thermal_zone0/trip_point_0_type:active
/sys/class/thermal/thermal_zone0/trip_point_3_temp:120000
/sys/class/thermal/thermal_zone0/trip_point_3_type:critical

Since commit e68b16abd91d ("thermal: add hwmon sysfs I/F") the driver
have been registering a sysfs entry if get_crit_temp() callback was
provided.  However when accessed, it was calling get_trip_temp() instead
of the get_crit_temp().

Fixes: e68b16abd91d ("thermal: add hwmon sysfs I/F")
Signed-off-by: Krzysztof Kozlowski <krzk@kernel.org>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/thermal/thermal_hwmon.c