* warranty of any kind, whether express or implied.
*/
+#define pr_fmt(fmt) KBUILD_MODNAME ": " fmt
+
#include <linux/module.h>
#include <linux/moduleparam.h>
#include <linux/types.h>
#define WDT_IN_USE 0
#define WDT_OK_TO_CLOSE 1
-static int nowayout = WATCHDOG_NOWAYOUT;
+static bool nowayout = WATCHDOG_NOWAYOUT;
static int heartbeat = -1; /* module parameter (seconds) */
static unsigned int wdt_max_duration; /* (seconds) */
static unsigned int wdt_tclk;
if (test_bit(WDT_OK_TO_CLOSE, &wdt_status))
orion_wdt_disable();
else
- printk(KERN_CRIT "WATCHDOG: Device closed unexpectedly - "
- "timer will not stop\n");
+ pr_crit("Device closed unexpectedly - timer will not stop\n");
clear_bit(WDT_IN_USE, &wdt_status);
clear_bit(WDT_OK_TO_CLOSE, &wdt_status);
if (pdata) {
wdt_tclk = pdata->tclk;
} else {
- printk(KERN_ERR "Orion Watchdog misses platform data\n");
+ pr_err("misses platform data\n");
return -ENODEV;
}
if (ret)
return ret;
- printk(KERN_INFO "Orion Watchdog Timer: Initial timeout %d sec%s\n",
- heartbeat, nowayout ? ", nowayout" : "");
+ pr_info("Initial timeout %d sec%s\n",
+ heartbeat, nowayout ? ", nowayout" : "");
return 0;
}
module_param(heartbeat, int, 0);
MODULE_PARM_DESC(heartbeat, "Initial watchdog heartbeat in seconds");
-module_param(nowayout, int, 0);
+module_param(nowayout, bool, 0);
MODULE_PARM_DESC(nowayout, "Watchdog cannot be stopped once started (default="
__MODULE_STRING(WATCHDOG_NOWAYOUT) ")");