.rating = 300,
.read = mpu_read,
.mask = CLOCKSOURCE_MASK(32),
- .shift = 24,
.flags = CLOCK_SOURCE_IS_CONTINUOUS,
};
static char err[] __initdata = KERN_ERR
"%s: can't register clocksource!\n";
- clocksource_mpu.mult
- = clocksource_khz2mult(rate/1000, clocksource_mpu.shift);
-
setup_irq(INT_TIMER2, &omap_mpu_timer2_irq);
omap_mpu_timer_start(1, ~0, 1);
- if (clocksource_register(&clocksource_mpu))
+ if (clocksource_register_hz(&clocksource_mpu, rate))
printk(err, clocksource_mpu.name);
}