All ALPS touchpads should respond to the "E6 report" command sequence:
E8-E6-E6-E6-E9. An ALPS touchpad should respond with either 00-00-0A or
-00-00-64.
+00-00-64 if no buttons are pressed. The bits 0-2 of the first byte will be 1s
+if some buttons are pressed.
If the E6 report is successful, the touchpad model is identified using the "E7
report" sequence: E8-E7-E7-E7-E9. The response is the model signature and is
byte 5: 0 1 ? ? ? ? f1 f0
This packet only appears after a position packet with the mt bit set, and
-ususally only appears when there are two or more contacts (although
-ocassionally it's seen with only a single contact).
+usually only appears when there are two or more contacts (although
+occassionally it's seen with only a single contact).
The final v3 packet type is the trackstick packet.